The conveyance air is then filtered through the fine filter bag section, located above the cyclone separator, before it is released to the atmosphere. Product particles are captured and returned, when the filter is purged, for proper storage and use. The result is a safe working environment, protecting personnel and equipment, with no product loss or pollution.
The PDC Vent Line filter and the PDC Ashing filter operate without the use of electricity or high pressure air. The units also operate without moving parts. Both units are portable and do not require installation. ASME certified filters are available for offshore use.
Note: All Photos Show Filter in Operation
ASME Filters on Drilling Rig
Does not require electricity. Captures vented particulates. | No pollution. No moving parts. |
Venting Various Tanks
Environmentally sensitive areas | Protect Personnel |
Vent multiple tanks with one filter. | Load or unload barges, rail cars, silos, supply boats, or trucks. |
Specifications:
Physical Dimensions:
Note:This is a closed loop filter. The filter operates without use of an ID fan. It utilizes cfm and air pressure that transfer products pneumatically. The vented air and the displaced air used are filtered in the transfer process. The filter removes the fines from the air stream and holds them until purging. Reversing the airflow through the filter cleans the bags and returns collected fines to storage.
Ratings:
Model: | #9-1400 | #16-2400 | #32-4800 |
Square Feet of Cloth Area | 45 | 80 | 156.48 |
Inlet CFM Max. | 3000 | 3000 | 4800 |
Loading Maximum @ 3% | 500 lbs | 800 lbs | 1600 lbs |
Normal CFM @ 1 psi | 1400 | 2400 | 4800 |
Filter CFM (sq ft of filter area and number of filter bags) is matched to the product being filtered.
Efficiency Rating @ 2800 Blaine 99.97
*Discharge Rate @ 5 Micron <00.05 lbs per hr. @ 100 lbs/cfm
Tel.: +359 2 857 32 25
Tel./Fax.: +359 2 857 32 25
mob.: +359 896 415 215
E-mail: m.al-obaidi@aspaeng.com